South East Network Installations, home

Structured cabling installation for offices and commercial buildings

Structured cabling is a planned, standards based cabling system that serves a whole building through a common set of cabinets, backbone links and outlets. We design and install it for offices and commercial buildings in London, Brighton and the South East.

Illustrative image of blue network cables bundled along a cable tray above a patched cabinet in an office

The service

A cabling system designed as a whole

Where data cabling describes the cable and the outlets, structured cabling describes the system they belong to. Instead of separate point to point runs, it takes an organised, standards based approach to cabling, so equipment can be moved, added or changed by patching rather than by recabling. Standards including ISO/IEC 11801 and, in Europe, EN 50173 set out how that system is organised.

It suits buildings with several floors, a main equipment room and a need to keep moves and changes simple. Backbone links are often fibre, which is covered under fibre optic cabling. A small site that needs only a handful of outlets may not need a full design, and plain cabling can be the better fit.

Teal fibre patch leads with yellow cables connected to a patch panel

How it is organised

The six parts of the system

  • Entrance facilities

    Where the provider's network ends and the cabling inside the building begins.

  • Equipment rooms

    Rooms that house the main equipment and the wiring serving the building.

  • Backbone cabling

    The links between entrance facilities, equipment rooms and telecommunications rooms.

  • Horizontal cabling

    Cabling from each telecommunications room to the outlets on the floor.

  • Telecommunications rooms

    Rooms or enclosures that connect the backbone cabling to the horizontal cabling.

  • Work area components

    The outlets and patch leads that connect end user equipment to the horizontal cabling.

What is included

What is included

  • Building survey

    Survey of risers, ceiling voids, cabinet positions and the routes between floors.

  • Cabling design

    A plan for cabinets, backbone and outlets, with a labelling scheme.

  • Backbone and floor cabling

    Links between the main equipment room, floor cabinets and outlets.

  • Cabinets, patch panels and outlets

    Network rack installation, then patch panels and outlets terminated and labelled, with patching kept tidy.

  • Testing and records

    Each link tested, with results and as installed records provided at handover.

  • Fire stopping

    Cable openings through fire resisting walls and floors need to be fire stopped, and the plan allows for this.

Our engineers hold

Qualifications held by our engineers

Between them, our engineers hold Microsoft, Cisco, CompTIA and fibre optic certifications, plus CSCS and ECS cards.

  • CompTIA Network+Networking
  • CSCS cardConstruction site skills
  • ECS cardElectrotechnical skills

Held by individual engineers. Not every engineer holds every qualification.

Tell us about your site and what you need.

An open tablet with a keyboard on a round wooden table in a modern office lounge

Cost

What affects structured cabling cost

A fixed price is not published here because it depends on the building. The survey and design come first, then a written quote.

Get a Quote

  • Size of the building

    Floors, floor area and the number of outlets and cabinets.

  • Routes and access

    Riser capacity, ceiling and floor voids, and the length of each route.

  • Category and testing

    Cat6, Cat6A or another specification, with the level of testing required.

  • Phasing and timing

    Whether floors are cabled while the building is occupied.

How it works

Structured cabling design and how a project runs

  1. Survey

    We inspect the building, risers and proposed cabinet positions.

  2. Design and quote

    A cabling plan with a written price for the agreed scope.

  3. Install

    Backbone first, then floor cabling, outlets and cabinets.

  4. Test and hand over

    Testing, labelling and as installed records, then handover.

FAQ

Common questions

Get a quote for building cabling

Tell us about your site and what you need.

Get a Quote

What are the structured cabling standards?

Its design and performance are governed by industry standards: ISO/IEC 11801 internationally, EN 50173 in Europe and ANSI/TIA-568. The cabling is specified to a category or class within the standard in use, for example Cat6A, and the test results at handover are measured against it.

How does it differ from ordinary data cabling?

Ordinary cabling can be a set of separate runs from a switch to each outlet. A structured system is organised in subsystems, so the same infrastructure can support several kinds of service, and changes are made at the patch panels rather than in the walls.

Does cabling need to be fire stopped?

Where cables pass through a fire separating wall or floor, the opening should be sealed with fire stopping so that the fire resistance of the element is not impaired. That is the guidance in Approved Document B, the fire safety guidance for buildings in England. The cabling plan should say how each opening will be dealt with.

Can the system be extended later?

Yes. Because it is built from standard parts joined at patch panels, extra outlets can be added from a floor cabinet and further floors linked to the main equipment room without disturbing existing links. That works well when the cabinets and containment are sized with spare capacity at the start, which leaves room for later patch panel installation.

Related services

Related services

Related guides

Related guides

Get a Quote

Plan your building cabling

Tell us about your site and what you need.

A black business desk phone on an office desk